How to deal with expired AB glue epoxy
31Oct
Andy 0條評論

How to deal with expired AB glue epoxy

How to deal with expired AB glue epoxy

Can the expired AB glue epoxy with PCB problems be saved besides scrapping?

What should you do with your AB epoxy resin if it expires? Scrap? Or continue to use it?

Many people think it's a pity that the Epox will be scrapped when it expires. What will be the problem if the expired Epox is not scrapped?

When using expired Epoxy, two major problems may basICally occur: failure to fully cure and decrease in surface resistivity (SIR) or volume resistivity (Volume Resistivity).

I believe that most of our friends can understand the problem of the inability of the epoxy to cure, because the epoxy will salivate outside the product and cause coSMEtic problems. In addition, it will lose the protection purpose of the epoxy glue dispensing/filling. However, it is not easy to understand the other "reduction of surface resistivity (SIR) or volume resistivity". However, we can talk about the impact of the reduction of resistivity first. The biggest problem is that it will cause leakage current. If it is light, it may increase the power consumption of the product, reduce the battery endurance, or even cause unstable operation of the product, Risk of crash or restart.


PCB


How can I ensure that expired Epoxy can still be used?

Our approach is to first distinguish the Date code of the Epox, then take an empty circuit board, find out two independent pads (pads) with a spacing of 0.1mm. It is recommended to measure whether there is impedance, cut off the connecting lines (traces) around them, and then weld a wire on each of them to facilitate the subsequent impedance measurement. Finally, put the expired Epox glue on the upper point, and the Epox must cover all welded pads, Then operate according to the normal curing procedure, so that you can not only test whether the epoxy can be fully cured, but also measure its resistivity and whether it is suitable for your product needs.

It is recommended that the minimum distance between two welding pads should refer to the actual situation of their respective companies. Be sure to find out the minimum distance between two welding pads at the epoxy coverage area. As for whether the flux after welding should be cleaned, it is recommended to make a group of clean and non clean. The impedance of pure epoxy can be measured if the flux has been cleaned, and the worst case is SIMulated SMT or repaired if the flux has not been cleaned. As for the measured impedance, our company's regulation is 1 × 108 Om or above is OK, but it is recommended to consult their RDs to see if your product design has higher impedance requirements.

Finally, why do expired Epoxies cause the above problems?

The following is just a personal opinion. The answer may not be correct. It is only for reference. If you have an expert on Epox, please come out and help correct the error.

Because the content of the epoxy will contain many macromolecular chEMIcal components and some will be doped with a SMAll amount of metal components, these heavier chemical components will slowly precipitate to the bottom of the liquid epoxy with the influence of time and gravity, and will even partially harden as the epoxy is placed for a long time, so the barrel of the early epoxy will require the package to be stored upside down, Before taking it out for use, it should be placed on the roller machine or vibrating shaker and shaken for more than 10 minutes, so as to evenly distribute these sediments into the liquid of Epoxy.

If hardened sediment is still found after the above shaking or rolling, be careful not to use this can of glue. If it is really necessary to use, the hardened sediment must be broken to dissolve it into the original epoxy liquid, otherwise there is a great chance to produce products with incomplete curing.

If it is necessary to use these expired AB glue epoxys, is there any way to verify their quality?

Our method is to select the AB glue of different date codes according to the date, and select one can for each type to try to inject glue. The key points of judgment are as follows:

Check whether the epoxy is completely cured. Cut the filLED glue for inspection.

(Refer to the illustration of the top picture) Select two welding pads on the circuit board with a distance of 0.1mm, connect a wire to each pad, and then add the epoxy on it until the two pads and solder joints are completely covered. After the epoxy is cured, measure the insulation resistance with a "megger". Our requirement is that it must be greater than 100M Om. Of course, it depends on the design of each product.

If the above two items are positive, fill the glue slowly one pot at a time. To ensure that the glue will really cure completely, make and keep the best record of each glue filling sample (dummy epoxy) to check the curing quality of the glue filling. In addition, the production line can also be required to place the cured products upside down in the manufacturing process. At this time, if there are products with incomplete curing, the epoxy will flow out, which can be visually inspected, so that the production line of the circuit board manufacturer can intercept the defective products, instead of waiting for customers to complain when they receive them.

點(diǎn)擊
然后
聯(lián)系
主站蜘蛛池模板: 西西人体444www大胆无码视频| 亚洲自偷自拍另类第1页| 久久中文字幕人妻熟女凤间| 亚洲国产精品久久亚洲精品| 天天做天天爱夜夜爽女人爽| 国产精品自在线拍国产电影 | 性高朝久久久久久久| 丰满岳乱妇在线观看中字| 无码国产69精品久久久孕妇| 欧美xxxx性bbbbb喷水| 国产性夜夜春夜夜爽1a片| 色综合天天综合高清网| a 'v片欧美日韩在线| 囯精品人妻无码一区二区三区99 | 午夜一区欧美二区高清三区 | 亚洲国产精品久久久久婷婷图片| 在线看片国产日韩欧美亚洲| 无码欧美黑人xxx一区二区三区| 女人被强╳到高潮喷水在线观看| 亚洲成色综合网站在线| 中文字幕日韩人妻在线视频| 精品av中文字幕在线毛片| 亚洲欧美日韩综合久久| 国产乱人激情h在线观看| 水蜜桃av无码| 中文字幕人成乱码熟女香港| 亚洲色成人www永久网站| 日日碰狠狠添天天爽超碰97久久| 中文人妻av久久人妻水密桃| 亚洲精品无码mv在线观看网站| 精品国产免费第一区二区三区| 国产破外女出血视频| 久草在线| 成人午夜特黄aaaaa片男男| 天天天天躁天天爱天天碰2018| 久久综合老色鬼网站| 免费精品国产人妻国语色戒| 丁香五月激情缘综合区| 上司的丰满人妻中文字幕| 免费看撕开奶罩揉吮奶头视频| 少妇性l交大片毛多|