Calibration circuit and fault diagnosis in pcb circuit board function test
29Nov
Andy 0條評論

Calibration circuit and fault diagnosis in pcb circuit board function test

Calibration circuit and fault diagnosis in pcb circuit board function test


PCB manufacturers, PCB designers and PCBA manufacturers explain the calibration circuit and fault diagnosis in the functional test of PCB PCB


Calibration circuit

Function test is often used for calibration or verifICation of analog circuits, including checking the interior of UUT (such as the IF part of RF circuit) to verify its work. To do this, test points or test pads may be required. One problem in high frequency design is that the relative impedance of the test point (path length, test pad size, etc.) plus the impedance of the probe will affect the performance of the circuit. This should be kept in mind when setting the test area. Automatic mechanical detection and needle bed fixture (discussed later in this article) only need a SMAll test area to ease this contradiction, mainly because compared with manual operation, The accuracy of the robot itself allows the tester to detect smaller areas.


pcb circuit board


fault diagnosis

If only functional test is used as pass/fail filter without measuring calibration point, this section can be skipped, because the probe may not be used in this application. In most cases, the function test is passed/faiLED because the function test is very slow in diagnosing faults, especially in the case of multiple faults. However, in some industries, functional testing is going deep into the manufacturing process, such as the manufacturing of cellular phones. Some manufacturers need to conduct certain key measurements at the PCB level, that is, during the assembly process before final assembly, which is determined by the nature of mobile phones that are easy to be eliminated. In other words, mobile phones are designed to be assembled at a lower cost, and they are not easy to disassemble. Therefore, functional verification before final testing can save rework costs and reduce possible waste products (because mobile phones will be damaged when disassembled).


Therefore, sufficient test points are required to probe PCB. For example, it is not convenient to check the J-shaped lead of a surface mounted device with a spacing of 20 mil, and BGA is even less possible. According to the recommendations of SMTA, the minimum spacing between test points is 0.040 inch. The spacing between pads depends on the element height, probe size, etc. around the test area. However, 0.200 inch spacing should be the minimum requirement, especially for manual exploration areas. Obviously, test fixtures and robotic probes are more accurate.

PCB manufacturers, PCB designers and PCBA manufacturers will explain the calibration circuit and fault diagnosis in the functional test of pcb PCB.

點擊
然后
聯(lián)系
主站蜘蛛池模板: 岛国在线无码高清视频| 动漫美女h黄动漫在线观看| 亚洲超碰无码色中文字幕97| 高潮内射免费看片| 男女男精品免费视频网站| 国产精品亚韩精品无码a在线| 99热这里只有精品国产免费免费 | 欧美牲交a欧美在线| 亚洲精品久久久久中文字幕二区| 国产亚洲精品久久yy5099| 国产成人精品午夜福利软件| 国产传媒18精品免费1区| 69无码| 少妇人妻偷人精品一区二区| 国产亚洲日韩妖曝欧美| 国产美女狂喷水潮在线播放 | 国产成+人欧美+综合在线观看| 99久久国产精品免费高潮| 亚洲爆乳精品无码一区二区| 久久久久青草线蕉综合| 在线观看国产亚洲视频免费| 中文字幕v亚洲日本在线电影| 国产午夜福利在线观看视频_| 国产亚洲欧美日韩在线观看一区 | 午夜视频体内射.com.com| 国产精品你懂的在线播放| 国产亚洲情侣一区二区无| 日欧137片内射在线视频播放| 色一情一乱一乱一区99av| 亚洲精品久久久久久久久久吃药| 亚洲欧美另类成人综合图片| 久久久久久亚洲精品a片成人| 午夜福利视频合集1000| 国内精品久久久久影院嫩草| 人妻少妇精品无码专区二区| 亚洲中文在线精品国产百度云| 亚洲夜夜性无码| 亚洲青青草原男人的天堂| 精品国产亚洲福利一区二区| 国产剧情福利av一区二区| 无码人妻h动漫中文字幕|